Fi Manual English | Lambert Lx 24
| Specification | Details | |:---|:---| | Product Type | Conventional (On-Demand) Combination Boiler | | Model Name | Lambert Lx 24 Fi | | Power Output | 24 kW | | Max. Heating Capacity | Approximately 160 m² (subject to building insulation) | | Dimensions (HxWxD) | 725 mm x 400 mm x 300 mm | | Weight | 38 kg | | Expansion Vessel Capacity | 6 liters | | Domestic Hot Water Flow Rate | 10.7 liters per minute | | Max. Radiator (CH) Temp | 20°C - 80°C | | Max. Domestic Hot Water (DHW) Temp | 30°C - 65°C | | Electrical Power Consumption | 135 W | | Electrical Protection Rating | IPX4D (Splash-proof) | | NOx Class | 3 (Environmental standard) | | Color | White |
Complete Guide and Instruction Manual for the Lambert Lx 24 Fi Boiler
: Ensure the gas valve is open and the power supply is connected. Press the
Tighten the valve clockwise completely. Do not over-pressurize past 2.0 bar. 4. Installation and Commissioning Guidelines Lambert Lx 24 Fi Manual English
This comprehensive guide serves as an English reference manual for the Lambert Lx 24 Fi boiler, covering its technical specifications, control panel functions, installation requirements, and troubleshooting steps. 1. Technical Specifications and Overview
For anyone using the Baymak Lambert LX 24 Fi gas boiler, having the right documentation is key for safe operation and troubleshooting. This wall-mounted, dual-circuit boiler is a reliable choice for heating areas up to 📘 Official Manual & Resources
Test the internal bladder pre-charge pressure using a standard tire pressure gauge while the boiler is fully depressurized. Recharge to approximately 1.0 bar using a manual air pump if needed. | Specification | Details | |:---|:---| | Product
Because it is a room-sealed appliance, the flue terminal must not be obstructed under any circumstances.
Confirms the burner is lit and actively heating.
: Features a closed combustion chamber (hermetic). Domestic Hot Water (DHW) Temp | 30°C -
Maintain minimum clearances around the boiler (typically 50mm on each side, 300mm at the bottom, and 200mm at the top) for maintenance access.
The pressure gauge should be checked regularly. If the pressure drops below 0.5 bar, the boiler may not start. To increase pressure: Locate the filling loop (usually under the boiler).
One of the most critical parts of any user manual is the error code section. Below is a comprehensive table of common error codes you may encounter on the Lambert Lx 24 Fi's display, along with their meanings and suggested solutions.