Ensure your factory power supply matches the voltage stamped on the unit’s serial plate (typically 460V/3PH/60Hz in North America).
Essential for processing PEEK, PPS, and LCP.
Built with a stainless steel heat exchanger and Incoloy heating elements for durability.
The unit will use compressed air to blow the remaining water out of the mold channels back into the return line, preventing hot water spills onto the factory floor.
Allows the operator to control either the motor speed or the flow rate, directly optimizing energy consumption. wittmann tempro plus d 360 manual exclusive
Standard water systems can boil at 212°F (100°C). To achieve stable temperatures up to 360°F (182°C), the D 360 is a pressurized system. It uses an internal gauge and control logic to maintain the water in a compressed liquid state, keeping the internal pressure at least 1 bar above the water's vapor pressure curve. This prevents cavitation (bubble formation) that can damage pumps and cause erratic temperature control, ensuring a smooth, efficient, and safe process.
Ensure all mechanical connections, electrical lines, and mold supply/return lines are securely tightened. Open all shut-off valves in the cooling water loop and the mold circuit. Step 2: Powering On and Self-Test
Before commissioning the Tempro Plus D 360, ensure the installation site complies with the following infrastructure demands: 1. Electrical Connections
: Temperature has dropped below the lower required limit. Accessing Advanced Service Configurations Ensure your factory power supply matches the voltage
Set the . This alerts you if the temperature difference between the supply and return lines exceeds a safe threshold (typically 5–10°F).
The TEMPRO plus D 360 is characterized by its pressurized system and specialized pump technology.
The unit features a line evacuating (mold purge) function, which uses air to clear water from the mold during changes, reducing mess and downtime. Maintenance & Service
The Manual Exclusive version of the Wittmann TemPro Plus D 360 offers several distinct features that set it apart from other machines: The unit will use compressed air to blow
What or behavior are you currently troubleshooting?
High-pressure magnetically coupled pumps (eliminates mechanical seal leaks)
When operating a water unit at 360°F (182°C), preventing the water from turning to steam is the paramount safety concern. The D 360 is a . The exclusive manual details how a pressure sensor constantly monitors the internal pressure. An automatic fill and drain valve system maintains this pressure so that it is at least 1 bar (approximately 15 psi) above the steam pressure curve for the given temperature. In simpler terms, it keeps the water under enough pressure to stay liquid, which is essential for stable and safe operation. This sophisticated level of control is precisely why the exclusive manual is mandatory reading for any technician servicing the unit.